Start/Stop & Speed Control: Execute remote soft start/stop profiles and fine-tune operating speeds within the 20–200 RPM range (±1 RPM accuracy).
Real-Time Operating Metrics: Track live current, voltage, speed, and torque to verify optimal well performance.
Remote Parameter Adjustments: Modify controller strategies and soft start profiles remotely to match changing well conditions.
Live Alerts & Safety Diagnostics: Receive instant anomaly alerts, rod-stick detection notifications, and supercapacitor backup status.
Remote Troubleshooting: Perform full digital diagnostics and system health checks directly through the dedicated SRD controller.

Start/Stop & Speed Control: Execute remote soft start/stop profiles and fine-tune operating speeds within the 20–200 RPM range (±1 RPM accuracy).
Real-Time Operating Metrics: Track live current, voltage, speed, and torque to verify optimal well performance.
Remote Parameter Adjustments: Modify controller strategies and soft start profiles remotely to match changing well conditions.
Live Alerts & Safety Diagnostics: Receive instant anomaly alerts, rod-stick detection notifications, and supercapacitor backup status.
Remote Troubleshooting: Perform full digital diagnostics and system health checks directly through the dedicated SRD controller.


Monitored continuously across 380–480 V operating ranges to detect electrical or mechanical load changes before they cause downtime.

Tracked in real time with permissible fluctuation management (±15%) to confirm system stability.

Live readout of direct-drive motor speed (20–200 RPM) with precise speed accuracy (±1 RPM).

Instant, clear status monitoring including soft start/stop status, rod-stick detection, and 0.5s brake response readiness.

Real-time torque readings up to rated 1,050 N·m (and overload up to 200%) to ensure smooth operation in high-viscosity and heavy oil wells.



Monitored continuously across 380–480 V operating ranges to detect electrical or mechanical load changes before they cause downtime.

Tracked in real time with permissible fluctuation management (±15%) to confirm system stability.

Live readout of direct-drive motor speed (20–200 RPM) with precise speed accuracy (±1 RPM).

Instant, clear status monitoring including soft start/stop status, rod-stick detection, and 0.5s brake response readiness.

Real-time torque readings up to rated 1,050 N·m (and overload up to 200%) to ensure smooth operation in high-viscosity and heavy oil wells.
Boremax leases and supports its direct-drive systems for operators across the United States. The underlying technology is backed by a manufacturing facility in Douliu and an extensive field history across demanding international basins—including high-sand, heavy oil, and high-viscosity applications.
14411 Catalina dr San Leandro CA 94576
© 2026 Boremax. All Rights Reserved.